阮丹平,张丁华,吴春云,沈赟.LED固化灯光照强度对光固化复合树脂聚合收缩的影响[J].口腔材料器械杂志,2013,22(1):28-32.
LED固化灯光照强度对光固化复合树脂聚合收缩的影响
Effect of light intensity on the polymerization shrinkage dynamics light-curing composite resin with light-emitting diode curing light
投稿时间:2012-08-27  修订日期:2012-09-17
DOI:10.11752/j.kqcl.2013.01.06
中文关键词:  光固化复合树脂  聚合收缩  光照强度  数字图像相关法
英文关键词:Light-cure composite resin  Polymetization shrinkage  Light intensity  Digital image correlation method
基金项目:上海市闵行区自然科学基金资助(2010MHZ40)
作者单位E-mail
阮丹平 上海市闵行区中心医院口腔科, 上海 201199 ruandanping1978@163.com 
张丁华 上海市闵行区中心医院口腔科, 上海 201199  
吴春云 上海市闵行区中心医院口腔科, 上海 201199  
沈赟 上海市闵行区中心医院口腔科, 上海 201199  
摘要点击次数: 868
全文下载次数: 0
中文摘要:
      目的:采用数字图像相关法动态研究LED光固化灯不同光照强度对光固化复合树脂聚合收缩的影响。方法:收集12颗大小接近的新鲜离体磨牙,随机分为3组,制备大小为2.0 mm×2.0 mm×2.0mm的邻(牙合)面洞形,洞面酸蚀冲洗后涂粘接剂光照10 s,充填3M Z350纳米复合树脂,邻面快速制造散斑,LED固化灯垂直(牙合)面光照40s,3组光照强度分别为300 mW/cm2、500 mW/cm2和800 mW/cm2,数码相机同步实时采集光照过程中试件表面散斑的变化序列图像,用数字图像相关法计算获得各序列图上逐个像素点水平方向(x)和垂直方向(y)位移,统计线性收缩率,描绘各像素点的时域变化曲线,并用SPSS 12.01统计软件包进行方差分析和配对t检验。结果: 3种光照强度下树脂x方向线收缩率分别为0.081%~0.486%、0.004%~0.316%和0.063%~0.560%,y方向线收缩率分别为0.088%~0.981%、0.003%~0.77%和0.157%~1.252%,3组之间差异有统计学意义(P<0.05);3组第20 s树脂游离面收缩x方向位移差异无统计学意义,y方向位移差异有统计学意义。结论: LED光固化灯500 mW/cm2光照时引起的树脂聚合收缩最小。
英文摘要:
      Objective: To compared the polymerization shrinkage of light cured composite resin in different light intensity cured by light一emitting diode(LED) curing light with digital image correlation method. Methods: 12 freshly extracted molars with similar size were divided randomly in three groups. The proximal surface were Single Bond 2 to plane and proximal-occlusal cavity(2.0mm×2.0mm×2.0mm) were prepared. Cavities were acid etched, sealed with single Bond 2 and filled by nanofilled composite resin (Z350-3M-ESPE,Vita shade A2). Proximal surfaces were dealt with random speckle. All the samples lighted vertically for 40 seconds,the light intensity was 300 mW/cm2,500 mW/cm2 and 800 mW/cm2 respectively. As light curing proceeded,the speckled images were collected by digital camera in real-time simultaneously. The digital image correlation analysis software was used to deal these images and achieve the displacement and strains in both horizontal and vertical direction on all pixel points, at last the linear shrinkage ratios were counted and the displacement at free surface at the 20th second were analyzed with SPSS 12.01 software package for ANOVA and stedent's test. Results: The linear shrinkage values were 0.081%-0.486%,0.004%-0.316%,and 0.063%-0.560% in horizontal direction and 0.088%-0.981%,0.003%-0.77% and 0.157%-1.252% in vertical direction respectively. Significant difference existed among the three light curing modes. Displacements in horizontal direction at free surface of the three samples at the 20th second was no statistically different (P>0.05),while displacements in vertical direction was different (P<0.05). Conclusions: The polymerization shrinkage of composite resin was minimal at 500mW/cm2 with LED light cure.