周志浩,熊再道,顾永春,陈秀春.无托槽隐形矫治器与固定矫治器对成人骨性Ⅲ类错牙合掩饰治疗的对比研究[J].口腔材料器械杂志,2023,32(2):104-108,146.
无托槽隐形矫治器与固定矫治器对成人骨性Ⅲ类错牙合掩饰治疗的对比研究
A comparative study of bracketless invisible appliances and fixed appliance in the treatment of adult skeletal class Ⅲ malocclusion
投稿时间:2022-09-26  修订日期:2023-01-30
DOI:10.11752/j.kqcl.2023.02.05
中文关键词:  无托槽隐形矫治器  骨性Ⅲ类错  头影测量  软组织  微种植体
英文关键词:Bracketless invisible appliances  Skeletal class Ⅲ malocclusion  Cephalometric measurement  Soft tissues  Micro-implant
基金项目:苏州市第九人民医院青年科研基金(编号:YK202115);苏州市吴江区“科教兴卫”项目(编号:WWK202114)
作者单位E-mail
周志浩 苏州大学附属苏州九院口腔科
苏州市第九人民医院, 苏州 215200 
 
熊再道 苏州大学附属苏州九院口腔科
苏州市第九人民医院, 苏州 215200 
xzdall4u@163.com 
顾永春 苏州大学附属苏州九院口腔科
苏州市第九人民医院, 苏州 215200 
 
陈秀春 苏州大学附属苏州九院口腔科
苏州市第九人民医院, 苏州 215200 
 
摘要点击次数: 338
全文下载次数: 294
中文摘要:
      目的 观察轻、中度成人骨性Ⅲ类错患者采用隐形矫治与固定矫治器结合微种植体整体远移下牙列治疗前后头影测量变化,评价其临床效果。方法 选取24例轻、中度高角成人骨性Ⅲ类患者按矫治器类型分成两组,均采用微种植体整体远移下牙列完成治疗,对每位患者治疗前后的X线侧位片进行测量分析。结果 所有患者治疗后,磨牙尖牙关系调整至中性,软组织侧貌得到改善。其中隐形矫治组U1-SN增大(9.99±7.74)°、L1-MP减小(1.71±2.96)°、颏唇角减小(2.35±3.02)°,上唇E线距增大(1.01±1.03)°,下唇E线距减小(0.74±0.51)° ;固定矫治组U1-SN增大(8.77±5.45)°、L1-MP减小(3.29±2.26)°、颏唇角减小(2.12±1.74)°,上唇E线距增大(0.52±0.67)°,下唇E线距减小(0.63±0.29)°。隐形矫治组L1-MP (t=1.245,P=0.034)减小量显著低于固定矫治组,且FH-MP (t=2.268,P=0.017)、SNMP (t=4.487,P=0.002)及ANS-Me (t=2.230,P=0.014)增加量显著低于固定矫治组,其余指标变化量组间比较差异无统计学意义。结论 无托槽隐形矫治器结合微种植体支抗整体远移下牙列可以有效纠上下牙矢状向不调,改善患者下颌前凸的的畸形面容,在下前牙转矩控制及垂直向控制上优于传统固定矫治器。
英文摘要:
      Objective The study aimed to evaluate the changes after bracketless invisible appliances and fixed appliance combined with miniscrew anchorage applied to distalize mandibular total arch in treatment of mild or moderate skeletal Class Ⅲ malocclusion. Methods 24 mild and moderate adult skeletal Class III patients were selected and divided into two groups according to the type of appliance. They were treated with miniscrew anchorage applied to distalize mandibular total arch. X-ray Cephalometric records were analyzed to assess the change of soft tissue before and after treatment. Results After treatment, the molar canine relationship was adjusted to neutral, and the soft tissue profile was improved. In the clear aligner group, U1-SN increased by (9.99±7.74)°, L1-MP decreased by (1.71±2.96)°, chin lip angle decreased by (2.35±3.02)°, upper lip to E-line distance increased by (1.01±1.03)°, lower lip to E-line distance decreased by (0.74±0.51)°; in the fixed appliance group, U1-SN increased by (8.77±5.45)°, L1-MP decreased by (3.29±2.26)°, chin lip angle decreased by (2.12±1.74)°, upper lip to E-line distance increased by (0.52±0.67)°, lower lip to E-line distance decreased by (0.63±0.29)°. The decrease of L1-MP (t=1.245, P=0.034) in the bracketless invisible appliances group was significantly lower than that in the fixed appliance group, and the increase of FH-MP (t=2.268, P=0.017) , SN-MP (t=4.487, P=0.002) and ANS-Me (t=2.230, P=0.014) in the bracketless invisible appliances group was significantly lower than that in the fixed appliance group. Conclusion Bracketless invisible appliances combined with Miniscrew anchorage can effectively correct the sagittal misalignment of upper and lower teeth, improve the deformity of mandibular protrusion. It is better than traditional fixed appliance in lower front tooth torque and vertical control.
查看全文  查看/发表评论  下载PDF阅读器
关闭