熊伯刚,牛光良,柴媛.不同镍钛根管预备系统对牙本质裂纹形成的影响[J].口腔材料器械杂志,2018,27(4):190-194. |
不同镍钛根管预备系统对牙本质裂纹形成的影响 |
Effects of different nickel-titanium root canal preparation systems on the dentin crack formation |
投稿时间:2018-03-11 修订日期:2018-06-02 |
DOI:10.11752/j.kqcl.2018.04.03 |
中文关键词: 牙本质裂纹 镍钛旋转系统 根管预备 |
英文关键词:Dentin crack Nickel-titanium rotary system Root canal preparation |
基金项目:首都卫生发展科研专项项目(编号:首发2014-2-7014) |
|
摘要点击次数: 774 |
全文下载次数: 909 |
中文摘要: |
目的 探讨不同镍钛旋转预备系统ProTaper Universal(PU)、ProTaper Next(PN)和X+File(X+)对牙本质微裂纹形成的影响。方法 将100颗下颌前磨牙随机分为4组(n=25)。组1为对照组(不做根管预备);组2为PU预备组(SX预备根管口,S1、S2、F1、F2预备直达工作长度);组3为PN预备组(Protaper Universal SX预备根管口,再用ProTaper Next X1、X2预备直达工作长度)。组4为X+预备组(Protaper Universal SX预备根管口,然后用X+File X1、X2预备直达工作长度)。预备完成后,所有离体牙在距根尖顶点3mm、6mm和9mm处垂直于牙体长轴做横切片,在根管显微镜下观察并记录裂纹形成情况。卡方检验对裂纹形成数目进行统计分析。结果 对照组未产生牙本质裂纹。镍钛旋转系统PU、PN和X+的牙本质裂纹发生率分别为60%,32%和24%(P<0.05)。仅PU组产生完全裂纹,且数目高于另外3组(P<0.05)。在根尖1/3处,PU组的不完全裂纹数高于另外3组(P<0.05)。PN组和X+组的牙本质裂纹发生率无明显差异(P>0.05)。结论 本研究中使用的3种镍钛根管预备系统均产生了牙本质裂纹。其中,X+File与ProTaper Next产生的牙本质裂纹较少,这可能与镍钛金属结构、尖端设计以及中心定位能力有关。 |
英文摘要: |
Objective The effects of different nickel-titanium rotary systems of ProTaper Universal (PU), ProTaper Next (PN) and X+File (X+) on dentin cracks formation were investigated.Methods One-hundred mandibular premolars were chosen and divided into 4 groups randomly (n=25). Gr 1 was as control group (no preparation); Gr 2 was as PU preparation group (the coronal one-thirds of the canals were prepared with Sx and S1, S2, F1 and F2 instruments were used for the working length); Gr 3 was as PN preparation group (the coronal one-thirds of the canals were prepared with Sx and X1, X2 were used for the working length); Gr 4 was as X+ preparation group (the coronal one-thirds of the canals were prepared with Sx and X1, X2 were used for the working length). All the prepared roots were horizontally sectioned at 3mm, 6mm and 9 mm from the apex. The cracks were observed by endodontic microscope. The cracks formation was recorded and analyzed with a Chi-square test.Results No dentin crack was observed in the control group. The incidences of dentin crack formation in different nickeltitanium rotating systems of PU,PN and X+ were 60%, 32% and 24% respectively. Only complete cracks were observed in PU group and the number was higher than that in three other groups (P<0.05). At 3mm level, the number of incomplete crack in PU group was higher than that in three other groups (P<0.05). There was no significant difference in the incidence of dentin crack formation between PN group and X+ group (P>0.05).Conclusion All three different nickel-titanium rotating systems of PU, PN and X+ used in this study caused dentin crack formation. Among them, X+File and ProTaper Next produced fewer dentin cracks. Nickel-titanium structure, tips design and central location capability may be the reason for the less dentin crack. |
查看全文 查看/发表评论 下载PDF阅读器 |
关闭 |